EasyManua.ls Logo

Ericsson CME 20 R6.1 - Installation Data Handling

Ericsson CME 20 R6.1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Data Handling
25 Installation Data Handling
The RBS contains a database which stores information relating to the
RBS as a whole, and to each RU within the RBS.
The most important purpose of the database is to provide effective aid
for:
General operation and maintenance
Fault diagnosis
Fault localisation
Traceability
The information stored in the database falls into one of two categories:
configuration information or history information.
The database is at least partly accessible to each of the following:
Other functions within the RBS
The operator via the OMT
The BSC via the A-bis interface
25.1 Concepts
CMRU Central Main RU. Subclass of Main RU.
An RBS has only one CMRU.
RU The smallest unit that can be handled on
site or in a repair center. Information
about the RU can be retrieved via OMT or
BSC.