EMC Capabilities for RBS 2302
The field strength of radiated emissions does not exceed the limits in
the following table at 3 m distance:
Table 55 Field strength of radiated emissions limits
Frequency of emission (MHz) Field strength
(uV/m) (dBuV/m)
30 - 88 100 40
88 - 216 150 43.5
216 - 960 200 46
>960 500 54
Specification references:
Code of Federal Regulations 47, FCC part 15 chapter 15.33, 15.109
40.4 Immunity
Note: Increased test level, extended frequency range and more
severe performance criteria are specified by Ericsson
internal EMC document.
40.4.1 Conducted Immunity on AC power ports
Fast Transient Test: RBS
Table 56 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-4, 1995
Test level 2 kV common mode between all lines and cabinet ground
reference.
Performance Criteria TT
Criteria TR
Note: see note 40.4
Fast Transient Test: PBC
Table 57 Fulfills the EEC self certification requirements according to:
Generic standard EN 50 082-1, 1992
Basic standard IEC 801-4, 1988
Mandatory test level 1 kV common mode between all lines and cabinet ground
reference.
Performance Criteria B
Note: see note 40.4
270 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved