EMC Capabilities for RBS 2302
40.3.3 Radiated Emission, Electric Field Emission
RBS
Table 52 Fulfills EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard I-ETS 300 609-1, 1997
Frequency range 30 MHz - 4 GHz
Operating mode Transmitters with full output power
PBC
Table 53 Fulfills EEC self certification requirements according to:
Generic standard EN 50 081-1, 1992
Basic standard EN 55 022, 1994
Limit Class B
40.3.4 Radiated Emission, TX Mode
RBS
The value of the spurious emission is at least 80 dB or 43 +10*log
(mean output power in Watt), whichever the lesser, below the mean
power of the unmodulated carrier.
The calculated radiated power limit for radiated emissions is -13 dBm.
Specification references:
Code of Federal Regulations 47, FCC part 2 chapter 2.993, 2.997 and
FCC part 24 chapter 24.238
40.3.5 Radiated Emission, None TX Mode
RBS
The radiated emission limit is specified up to the frequency shown in
the following table:
Table 54 Radiated emission limit
Highest frequency generated or used in the
device or on which the device operates or tunes
on (MHz), Emission (MHz)
Upper frequency of measurement
range (MHz)
<1.0705 30
1.0705 - 108 1000
108 - 500 2000
500 -1000 3000
>1000 5th harmonic of the highest freq. or
40 GHz which ever is lower
EN/LZT 123 2697 R5A