EMC Capabilities for RBS 2302
Surge Test: RBS
Table 58 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-5, 1995
Pulse shape 1, 2/50 (8/20) us
Test level 1 kV common mode between all lines and cabinet ground
reference. 0.5 kV differential mode between line and line.
Performance Criteria TT
Criteria TR
Note: see note 40.4
Surge Test: PBC
Note: see note 40.4
RF Common Mode: RBS
Table 59 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-6, 1996
Frequency range 150 kHz - 80 MHz
Test level 3 V(rms)
Performance Criteria CT
Criteria CR
Note: see note 40.4
RF Common Mode: PBC
Note: see note 40.4
Voltage Dips and Interruptions on AC Power Ports, RBS/ PBC
Table 60 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-11, 1994
Test level 1 Voltage dip, 30% reduction of nominal voltage during 10 ms
Test level 2 Voltage dip, 60% reduction of nominal voltage during 100 ms
Test level 3 Voltage dip, >95% reduction of nominal voltage during 5000 ms