EMC Capabilities for RBS 2302
Performance Criteria TT
Criteria TR
Level 1 without battery back-up
Level 2 and 3 with battery back-up
40.4.2 Conducted Immunity on DC power ports
Fast Transient Test: RBS
Table 61 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-4, 1995
Test level 1 kV common mode between all lines and cabinet ground reference.
Performance Criteria TT
Criteria TR
Note: see note 40.4
Fast Transient Test: PBC
Table 62 Fulfills the EEC self certification requirements according to:
Generic standard EN 50 082-1, 1992
Basic standard IEC 801-4, 1988
Test level 0.5 kV common mode between all lines and cabinet ground
reference.
Performance Criteria B
Note: see note 40.4
Surge Test: RBS, PBC
Note: see note 40.4
RF Common Mode: RBS
Table 63 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-6, 1996
Frequency range 150 kHz - 80 MHz
Test level 3 V(rms)
Performance Criteria CT
Criteria CR
Note: see note 40.4
272 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved