Synchronization
18.4.4 Locking to the Reference Source
Limited synchronism is reached within 4 minutes from function
initiation. Calls can be established but performance criteria are not
fulfilled, i.e. the risk of dropped calls is higher.
The frequency error is less than 0.5 ppm after 4 minutes.
The timeout for locking is 6 minutes.