Operation and Maintenance Support
Receiving application software
Activation of application software
pending
Configuration activity, which may take
more than 10 s to complete, in progress
Priority "Flashing" has highest priority followed
by "On". "Off" has lowest priority
There is one Operational indicator per cabinet.
Local mode (yellow)
On The RU is in local mode
At restart: Explicit test of indicators
Flashing Change of mode is in progress
Off The RU is in remote mode
There is one Local Mode indicator per cabinet.
External Alarms (yellow)
Off No external alarms are active
On One or more supervised external alarms
are active
At restart: Explicit test of indicators
There is one External Alarms indicator per RBS.
Reduced Capacity (yellow)
Off All TDMRUs are operational
On At least one TDMRU is not operational
At restart: Explicit test of indicators
There is one Reduced Capacity indicator per cabinet.
AC Power On (yellow)
Off No AC power supply
On AC power supply
At restart: Explicit test of indicators
There is one AC Power On indicator per cabinet.
Battery Fault (yellow)
Off Battery connected
On Battery disconnected or faulty
156 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved