Operation and Maintenance Terminal
28.3.12 Faults
The following user functions, related to fault information, are available
in the OMT:
Monitor current fault status, read the fault status from the RBS
and display changes continuously.
Display fault info, display the current fault information for a
specific object such as an RU or a PCM line.
The functions above are normally used in connection with:
Site acceptance (monitor current fault status).
Maintenance (display fault info).
28.3.13 Work Session
The concept of Work Sessions is essential to provide easy use of the
OMT. By executing a work session, the user is guided through the
views and provided with helping instructions. A typical work session
includes all the guidance necessary for the user to complete a normal
execution of an O & M process.
There are a number of predefined work sessions included in the OMT
intended for the major O & M processes: installation test and
maintenance. Further, the customer may define his own set of work
sessions, giving maximum support to his own O & M organisation.
The following user function, related to work sessions, is available in the
OMT:
Execute, execute a work session.
The function above is normally used for general purposes.
28.3.14 Remote OMT
A connection between the RBS and a remotely connected OMT can be
established. The remote OMT is placed at a BSC site.
The Remote OMT and the locally connected OMT are not
interchangeable with each other. They are two separate products
performing the same functions.
All functions available in a locally connected OMT are also available in
a remotely connected OMT.
The following user functions, related to the Remote OMT, are available:
Switch CMRU to local mode, the CMRU is switched into local
operation.
Switch CMRU to remote mode, the CMRU is switched into
remote operation.
Reset CMRU, the CMRU is reset.
Display CMRU operational state, the CMRU operational state is
displayed.
The functions above are used for general purposes.