EasyManua.ls Logo

Ericsson CME 20 R6.1 - Page 197

Ericsson CME 20 R6.1
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transmission Interface Handling G.703 2048 kbit/s
The number of unavailable seconds for each direction is reported after
each BI.
32.3.6 Administration
Supervision of transmission faults and transmission quality can be
performed in different ways. With the help of parameters, the
supervision can be configured to meet a wide range of requirements.
The configuration parameters can only be changed when the AO DP is
in state “Disable”. The parameters of interest are given below:
The configuration parameter N
Defines the threshold number (SES) for commence, and
cease, of CSES
Value range is 5-60
Default value is 10
The parameters P and Q
Used for defining unavailable state
Value range is 5-15 s
Default value is 10 s
The parameters N1 and N4
Define the threshold numbers for ES and SES. Value
range and default values are listed below:
Table 23 Parameters N1-N4
Parameter Value Range Description (number of...)
N1 805 1-1000 CRC-4 errors for SES and E-bits equal to "0"
N2 - Not used
N3 - Not used
N4 28 1-100 Frame errors for SES
The configuration parameter T
The parameter T defines the time interval for ERATE
supervision
Value range is 1-5 s
Default value is 2 s
The configuration parameter AFT
The configuration parameter AFT defines the Alarm
Filtering Time for all the fault supervision functions
Value range is 50-5000 ms
Default value is 125 ms
196 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved

Table of Contents

Related product manuals