Channel Distribution Function
35.3.5 Multidrop bypass
This function is only valid if it is supported by the hardware.
The function handles transparent connection from PCM-A to PCM-B
during such times that normal multidrop function is unavailable. This
can be due to:
Power off
Fatal software fault
Fatal hardware fault
Reset button on CMRU is pushed
BSC ordered reset
Replacement of RBS
The multidrop connected RBSs are connected so that each RBS
uses its port A towards the BSC and port B towards the next
RBS. The latter RBS is connected in the same way with port A
towards the previous RBS, port B towards the next RBS, and so
on. Figure 46 on page 226 illustrates the case with two RBSs and
with the first RBS in bypass mode.
04_0301A
BSC
RBS 1
CMRU
A
B
RBS 2
CMRU
A
B
Figure 46 Linear Cascade connection with bypass
When switching to and from bypass mode, a disturbance will occur on
the PCM line.
226 (306)
EN/LZT 123 2697 R5A
1998-08-13
© Ericsson Radio Systems AB
All Rights Reserved