EMC Capabilities for RBS 2302
40.4.5 Conducted Immunity For Direct Lightning Strike
RBS, PBC:
Note: see note 40.4
40.4.6 Radiated Immunity of enclosure port, electric fields
RBS
Table 70 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-3, 1995
Test level 3 V/m
Frequency range 80 MHz - 1 GHz
Performance Criteria CT
Criteria CR
Note: see note 40.4
PBC
Table 71 Fulfills the EEC self certification requirements according to:
Basic standard IEC 801-3, 1984
Test level 3 V/m unmodulated signal
Frequency range 27 MHz - 500 MHz
Performance Criteria A
Note: see note 40.4
40.4.7 Radiated Immunity of enclosure port, magnetic fields 50/60 Hz
RBS, PBC:
Note: see note 40.4
40.4.8 Electro-static Discharges, Immunity of enclosure port
RBS
Table 72 Fulfills the EEC type approval certification requirements according to:
Product standard prETS 300 342-3, October 1997
Basic standard EN 61 000-4-2, 1995
Test level Contact discharge 4 kV
Air discharge 8 kV