Product Specification for RBS 2302
5.8.9 Dependability
Technical Lifetime
The RBS is designed for a technical lifetime of 20 years (24 hours
operation).
Preventive Maintenance
The RBS has the following availability performance.
Action Interval
Mean repair time (MRT) < 60 minutes
Mean time between failures (MTBF) <8.5 years
Mean accumulated down time (MADT) <6 minutes/year (time to reach
the site is not included)
These preventive maintenance conditions must be fulfilled to guarantee
the availability figures above.
Action Interval
Change of battery < 5 years
Change of lightning protection equipment <10 years
Calibration of "optional" synchronisation oscillator < 3 years
5.8.10 Installation
A quick and easy installation procedure is provided. If the installation
preconditions are met, the RBS can be installed in less than 30 minutes.
A minimum of tools and instruments are required when installing an
RBS.
Preconditions
It is possible to adjust the RBS in vertical direction ± 10
.
Wall mounting with no visible cables is supported.
The initiation of the BSC is prepared.
The transport network is available
1)
at the site
Mains power is available at site
Preinstalled antennas and feeders are available
1)
Wall fixture is preinstalled
Favourable geographic location and environment (means higher
than -10
C, no precipitation and easy access to the site)
1)
"available" means: accessible and with specified function.