66
iPlex Installation and Hardware Specification Guide
You may tighten with your fingers or by using a Phillips #1 screw driver.
Troubleshooting Submodule Installation
If a submodule does not respond after inserting it into the carrier card, check the
following.
ASI In/Out 1
If the activity LEDs do not illuminate shortly after booting up, the board may
be faulty, or the carrier card has not initialized it correctly.
2
If the RDY LEDs continue to blink for more than two minutes, then the
submodule may be faulty.
In either case, contact TANDBERG Television Customer Support.
Encoders If the RDY LED never illuminates, the encoder may be faulty or the iPlex has not
initialized it correctly. Contact TANDBERG Television Customer Support.
ATM Adapter If the yellow LED illuminates and does not start blinking, the ATM adapter is hav-
ing a problem initiating. Contact TANDBERG Television Customer Support.
4
3
2
1
CONTROL
R
EDU
N
DA
NC
Y
CONS
OL
E
A
L
A
RM
GE
1
GE
2
1
00
/
2
40 V
A
C
~
6
A
A
U
D
I
O
MPEG-2 ENC
CI/Y/SDI
C2/C
RDY ACT
A
U
D
I
O
MPEG-2 ENC
CI/Y/SDI
C2/C
RDY ACT
A
U
D
I
O
MPEG-2 ENC
CI/Y/SDI
C2/C
RDY ACT
MPEG-2 ENC
CI/Y/SDI
RDY ACT
A
U
D
I
O
C2/C
NOTE
A faulty ASI submodule may prevent an iPlex from booting.