S0740 800 152/E061012/P36
-- 3 3 --
ci01i_ma6u6c
MMA WELDING
Settings
Settings Setting range In steps of Default setting
Hot start
1)
ON or OFF -- OFF
Hot start time 1--30 1 10
Arc force 0--10 0.5 3
Current
2)
16 -- 500 A 1A 164 A
Dimensions METRIC or INCH -- METRIC
Panel enable OFF or ON -- ON
Automatic save
3)
OFF or ON -- OFF
Limits
3)
OFF or ON -- OFF
Lock code
3)
OFF or ON -- OFF
1)
This function cannot be changed while welding is in progress.
2)
Maximal current depends on which machine type is used.
3)
Contact an authorised ESAB service engineer to activate this function.
The synergy line on delivery rutile electrode 4.0 mm.
ARC--AIR GOUGING
Settings
Settings Setting range In steps of Default setting
Wire diameter 4.0--8.0 mm 1mm 4.0 mm
Voltage 8-- 60 V 0,25 V (Displayed with
one decimal.)
37.0 V
GENERAL FUNCTIONS
Remote control unit
Machines with intergral control panels should have program version 1.21 or higher, in order
for the remo te control to function correctly.
Control panel’s behaviour on connection of the remote control adapter
S The display freezes in the menu showing when the remote control adapter is
connected.
Measurement and setting values are updated, but only displayed in those menus in
which the values can be shown.
S If a fault code symbol is displayed, it cannot be removed until the remote control
adapter has been disconnected.
S With 10--programme remote control units, it is possible to switch between memory
positions 1 to 10. If memory position 2 is empty, the values from position 1 are retained.