E200P Operation Manual
12
SINGLE
: DestPosX Unit: mm
X = 100.50 Y = 120.05
XP = 55.00 YP = 0.00
DX = 20.00 HT = 2.00
DLY= 2.00 PP = 150
CP = 100 OPN= 0.00
XP = 55.00
Figure 3-2 The SINGLE page
The description of the SINGLE parameters is as shown in Table 3-1.
Table 3-1 The description of the SINGLE parameters
Parameter Default Range Unit Description
XP
0.00
0~9999.999
mm/inch
Program position of X axle.
YP
0.00
0~9999.999
mm/inch
Program position of Y axle.
DX
0.00
0~9999.999
mm/inch
Retract distance of X axle.
HT 0.00 0~99.99 s
The interval time from LDP signal to
decompression process.
DLY 0.00 0~99.99 s
In case of single step, delay time for
X-axle retracting.
PP 0 0~9999 -
The number of processing workpiece
in this program.
CP 0 0~9999 -
PP=0: this value is the current
work piece.
PP>0: this value is the remain
work piece.
OPN 0.00 0~999.999 mm/inch
After bending, the distance of the
Y-axis opening.