6.1 Instructions to maintenance
In order to use this system safely and properly, follow the instructions.
When power is on or system operates normally, do not open cover plate or panel as
it may damage the components.
Professionals shall do Wiring and inspection.
Do not touches IC pin or contact of joint.
Do not place system on metal product that may cause power leakage, or on wood,
plastic or vinyl product, which has static electricity.
If self-diagnosis error occurs to the system, determine details in accordance with
warning instructions and eliminate causes to error. Ensure safety. Rerun when
warning is removed. (Refer to Appendix 1 Warning list and instructions)
Before operation, determine and adjust program and each parameter.
Do not add voltage values excluded in operating manual on any binding post.
Otherwise damage or breakage may be caused.
Do not misconnect terminals. Otherwise, damage or breakage may be caused.
Do not mistake polarity (+/-). Otherwise, damage or breakage may be caused.
Control line and communication cable shall not be together with or close to principal
line and power harness. Their distance between each other shall be over 100mm
during installation.
6.2 Routine inspection
For routine inspection, please refer to Table 6-1.
Table 6-1 Routine inspection
No.
Inspection item
Standard content
Standard
specification
Treatment
1
Basic installation
status of the
system
Check set screw for
loosening, and
check seal for drop.
Be installed properly.
Fasten screw.
2
IO port connection
status
Check IO port
connection for
loosening
Correct wiring.
Correct wiring.