(Translation of the original operating instructions) 2098039-20-02/20
Safety Output
Read Head
Safety Inputs
Read Head
Safety Output
SafetyInputsSafetyInputs
Safety Output
Y-distributor
Y-distributor Y-distributor
Terminating plug
ET200
4/8 F-DI4 F-DO
-X1-X1
Digital
Output
PWR
Supply of
the control
DI4 DI0DO..M DO..P DO
2
DC24V
3
M
2
UB
8
RST
6
IA
1
IB
X2:3
LED1
X2:4
UCM
X2:5
J
7
0V
5
OUT
3
OA
4
OB
X2:1
0V(UCM)
2
UB
8
RST
6
IA
1
IB
7
0V
5
OUT
3
OA
4
OB
2
UB
8
RST
6
IA
1
IB
7
0V
5
OUT
3
OA
4
OB
24
0V
CES
CET
CES
Figure 5: Connection example for mixed series connection (2 x CES and 1 x CET) to ET200