EasyManua.ls Logo

Evco EVFTFT618 - Page 37

Evco EVFTFT618
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EVCO S.p.A. EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224
Page 37 of 62
Pr4
Humidity transducer error.
Solutions:
- check the integrity of the transducer
- check the device-transducer connection
- check the humidity relative to the cabinet.
Main consequences if parameter rU0 is set at 0:
- if the error occurs during “stand-by”, cycles that envision humidity management cannot be
launched
- if the error occurs during the execution of a cycle that envisions humidity control, the cycle will
be interrupted.
rtc
Clock error.
Solutions:
- set the real date and time again.
Main consequences:
- the device will not be able to start automatic cycles
- any automatic cycles in progress will be blocked.
ErC
User interface-control module compatibility.
Solutions:
- check that the user interface and the control module are compatible.
Main consequences:
- interruption of cycle in progress.
ErL
User interface-control module communication error.
Solutions:
- check user interface-control module control module.
Main consequences:
- interruption of cycle in progress

Table of Contents