Pr4
Humidity transducer error.
Solutions:
- check the integrity of the transducer
- check the device-transducer connection
- check the humidity relative to the cabinet.
Main consequences if parameter rU0 is set at 0:
- if the error occurs during “stand-by”, cycles that envision humidity management cannot be
launched
- if the error occurs during the execution of a cycle that envisions humidity control, the cycle will
be interrupted.
rtc
Clock error.
Solutions:
- set the real date and time again.
Main consequences:
- the device will not be able to start automatic cycles
- any automatic cycles in progress will be blocked.
ErC
User interface-control module compatibility.
Solutions:
- check that the user interface and the control module are compatible.
Main consequences:
- interruption of cycle in progress.
ErL
User interface-control module communication error.
Solutions:
- check user interface-control module control module.
Main consequences:
- interruption of cycle in progress