96
ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS
Dynamic Information
Dynamic information is viewed while the outboard
is running. Changes in data, such as voltages or
temperatures, are shown as they happen.
v
Stored Service Codes (Faults)
Service codes are stored if an abnormal condition
occurs while the outboard is running.
The Stored Faults screen of the diagnostics soft-
ware shows the code number, the number of
times the event occurred, and operating hours of
first and last occurrences.
Hard Faults
A hard fault is a service code that currently exists.
Hard faults become stored faults only if the out-
board is running.
Persistent Faults
The Persistent Faults screen keeps a history of all
previously stored codes, including code number,
the number of times the event occurred, and oper-
ating hours of the last occurrence.
Persistent faults cannot be erased.
Static Tests
Static Tests allow diagnostic testing of system
components while the outboard is NOT running.
Engine Monitor Screen 006539
Stored Faults Review Screen 006625
Hard Faults Review Screen 006626
Static Tests Screen 006772

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Evinrude & Johnson E90DPLSCB and is the answer not in the manual?

Evinrude & Johnson E90DPLSCB Specifications

General IconGeneral
BrandEvinrude & Johnson
ModelE90DPLSCB
CategoryEngine
LanguageEnglish

Related product manuals