EasyManua.ls Logo

EWM Taurus 355 Basic TDM - Reset to Factory Settings; The Special Parameters in Detail

EWM Taurus 355 Basic TDM
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Design and function
Special parameters (advanced settings)
46
099-005221-EW501
16.04.2014
5.14.2 Reset to factory settings
NOTE
All special parameters saved by the user will be overwritten by the factory settings!
Operating
element
Action
Result
Display
left
right
Switch off welding machine
Press and hold push-button
Switch on welding machine
Release push-button
Wait for about 3 s
Switch off the welding machine and restart in
order to implement the changes.
5.14.3 The special parameters in detail
Ramp time for wire inching (P1)
The wire inching starts with a speed 1.0 m/min for 2 secs. It is subsequently increased to a ramp function
to 6.0 m/min. The ramp time can be set between two ranges.
During wire inching, the speed can be changed by means of the welding parameter setting rotary dial.
Changing the speed has no effect on the ramp time.
Latched/special-latched tap start (P9)
In latched tap start operating mode it is possible to switch straight to the second step by tapping the
torch trigger; it is not necessary for current to be flowing.
The welding can be halted by pressing the torch trigger for a second time.

Table of Contents

Other manuals for EWM Taurus 355 Basic TDM

Related product manuals