DIAMANT Pro
7
All versions
CHANGING THE GROUP GASKET
1. To remove the porta-lter, use a
straight-blade screwdriver to release
the shower by prying down with
medium force.
4. Remove the lter basket(A), then
place the new gasket and shower(B)
into the porta-lter(C).
2. Remove the shower and gasket.
5. Preheat the gasket to soften the rubber. A - heat the gasket for 15 seconds
using the water from the hot water outlet, or B - place the gasket, shower,
and porta-lter in hot water for 30 seconds.
3. Remove and discard the old gasket.
Insert the new gasket (chamfer and
EXPOBAR logo facing up) into the
shower.
15s
30s
99
O
C
A
A
B
C
B
> 65
O
C
WARNING:
The water from the water tap is very hot! Handle with care to prevent scalding or burns.