EasyManua.ls Logo

Expobar Diamant Pro - Routine Maintenance Schedule; Service Intervals

Expobar Diamant Pro
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIAMANT Pro
8
Service intervals
ROUTINE MAINTENANCE SCHEDULE
Main components Part No.
Months (Cycles)
6 (12500) 12 (25000) 18 (37500) 24 (50000)
Boiler
Non suction valve 65000210 Replace Replace
Base Plate Electrovalve 60000105 Replace
Thermics Sup. Adaptor
1/2 X 1/2
30000200 Check Replace
Thermics Inf. Adaptor-
1/2X1/2X1/4
30000210 Check Replace
3/8 Safety Valve
65000100
Check Check
Brewing group
Electrovalve 220V 60000112 Replace
Shower 75000010 Replace Replace Replace Replace
8mm group head gasket 75000081 Replace Replace Replace Replace
Ta p s
Steam tap body 15000338 Clean Replace
Water tap electrovalves
60000124 +
60000125
Replace
SmartSteam electrov. 60000120 Replace
Motor-pump
Pump head 60000030 Replace
Retention Valve 65000010 Replace
Pump Bypass 30400055 Replace
Important:
Always conduct the 6 month service intervals without delay to ensure excellent performance of
the machine and to ensure full warranty coverage.