DIAMANT Pro
8
Service intervals
ROUTINE MAINTENANCE SCHEDULE
Main components Part No.
Months (Cycles)
6 (12500) 12 (25000) 18 (37500) 24 (50000)
Boiler
Non suction valve 65000210 Replace Replace
Base Plate Electrovalve 60000105 Replace
Thermics Sup. Adaptor
1/2 X 1/2
30000200 Check Replace
Thermics Inf. Adaptor-
1/2X1/2X1/4
30000210 Check Replace
3/8 Safety Valve
65000100
Check Check
Brewing group
Electrovalve 220V 60000112 Replace
Shower 75000010 Replace Replace Replace Replace
8mm group head gasket 75000081 Replace Replace Replace Replace
Ta p s
Steam tap body 15000338 Clean Replace
Water tap electrovalves
60000124 +
60000125
Replace
SmartSteam electrov. 60000120 Replace
Motor-pump
Pump head 60000030 Replace
Retention Valve 65000010 Replace
Pump Bypass 30400055 Replace
Important:
Always conduct the 6 month service intervals without delay to ensure excellent performance of
the machine and to ensure full warranty coverage.