MESSAGES AND ALARMS
Fault in volumetric counter N /
Flow fault detected in counter N
Alarm
Counter Vol. Gr. N
Check that the machine is receiving water.
Time-out alarm
Boiler filling
Temperature gauge fault
Sensor fault
Service the machine.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold down the
1 Short Espresso
and 1 Long Espresso buttons.
Turn on the machine.
Service
999999999
Regenerate the filter.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold down the
2 Short Espressos
and 2 Long Espressos buttons.
Turn on the machine.
Change the filter
999999999
If boiler filling time exceeds the programmed time (2 minutes), all of the button panel lights will flash and the
machine will be disabled. To re-enable it, turn the machine off and on again at the power switch.
If the electronic control panel does not receive a pulse from the volumetric counter (coffee too fine or
volumetric counter fault) within 5 seconds of pressing one of the espresso buttons, the light for the dose
selected will start to flash. To turn it off, press the dose button again.
Maximum dispensing time. As a safeguard, all dose settings have a maximum dispensing time of 5 minutes.

Table of Contents

Other manuals for Expobar G-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Expobar G-10 and is the answer not in the manual?

Expobar G-10 Specifications

General IconGeneral
BrandExpobar
ModelG-10
CategoryCoffee Maker
LanguageEnglish

Related product manuals