EasyManuals Logo

Extreme Networks ExtremeSwitching 210-12t-GE2 User Manual

Extreme Networks ExtremeSwitching 210-12t-GE2
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
RPS-500p Connector
See Figure 48 and Table 31 on page 77 for pin locations and function.
Note
The following information is for troubleshooting purposes only. For proper operation, use only
the 1 meter RPS cable supplied with the RPS-500p. This cable is specially designed for this
application and meets all necessary regulatory and safety standards. The use of non-
approved cables will void your warranty.
Figure 48: RPS-500p Connector Pin Locations
Table 31: RPS-500p Connector Pins
Pin Function Pin Function
1 - 55 V return 8 Ground
2 - 55 VDC 9 No connection
3 12 VDC output 10 RPS present
4 12 VDC output 11 Status 1 Status
5 12 VDC output 12 Status 2
6 12 VDC output 13 Power good
7 Ground 14 Ground
Power Cord Requirements for AC-Powered Switches and AC
Power Supplies
An AC power cord is not included with the AC power supply.
Power cords used with AC-powered switches or with Summit AC power supplies must meet the
following requirements:
The power cord must be agency-certified for the country of use.
The power cord must have an IEC320-C13 connector for connection to the switch or power supply.
Technical
Specifications
ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide 77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks ExtremeSwitching 210-12t-GE2 and is the answer not in the manual?

Extreme Networks ExtremeSwitching 210-12t-GE2 Specifications

General IconGeneral
BrandExtreme Networks
ModelExtremeSwitching 210-12t-GE2
CategorySwitch
LanguageEnglish

Related product manuals