DTP CrossPoint 4K Series Matrix Switchers • Programming Guide 57
X2@ = Name 12 characters maximum
upper- and lower-case alphanumeric characters and _ / and spaces are valid.
NOTE: The HTML language reserves certain characters for specific functions (see Special Characters on page 72).
X2# = Scaler preset 001 – 128
X2$ = Preset number 01 – 32
X2% = Lock mode 0 = Mode 0 1 = Mode 1 2 = Mode 2 (default)
X2^ = Firmware version number to second decimal place (x.xx)
X2& = Verbose firmware version-description-upload date/time (see the
Query firmware version (verbose) command on page 63).
X2* = Voltage Positive or negative voltage and magnitude
X2( = Internal temperature Degrees Celsius
X3) = Picture adjustments 000 through 127 (064 = default)
X3! = Position and size ±10240 Horizontal position specified from left,
Vertical position specified from top
X3@ = Active pixels and active lines Dependent on the input signal and selected scaling.
X3# = Aspect ratio fill or follow 1= fill (default) 2 = follow
X3$ = Overscan percentage 0 = 0% (default) 1 =
2.5%
2 = 5.0%
X3% = Test pattern 00 = Disable (default)
01 = Crop 04 = Color bars
02 = Alternating pixels 05 = Grayscale
03 = Crosshatch 06 = Blue mode
X3^ = Scaler preset available 0 = Unavailable 1 = Available
X3& = Duration 0 = Output sync instantly disabled when no active video input is selected
001 through 500 (seconds)
501 = Output sync never times out (default)
X3* = Screen saver status 0 = Active input detected, timer is not running
1 = No active input, timer is running, output sync is still active
2 = No active input, timer is expired, output sync is disabled
X3( = Scaler output resolution and rate See the table on page 67.
X4) = Switch effect 0 = Cut (default) 2 = Seamless fade
1 = Fade through black 3 = Seamless cut
X4! = Logo number 00
–
16
(
00
= no logo)
X4@ = Captive screw or UART 0 = Captive screw RS-232 insert (default) 1 = Ethernet RS-232 insert (UART)
X4#
= Port number 02 — 09 = UARTs 2 — 9 (DTP input and output ports)
02 = Input 7 06 = Output 5
03 = Input 8 07 = Output 6
04 = Input 9 08 = Output 7
05 = input 10 09 = Output 8
X4$
= Baud rate 300*, 600*, 1200*, 1800*, 2400*, 3600*, 4800*, 7200*, 9600, 14400*, 19200,
28800*, 38400, 57600*, 115200 (default = 9600)
* Valid for serial port insert commands only
X4%
= Parity odd, even, none, mark, space (only the first letter required) (n = default)
X4^
= Data bits 7, 8
X4&
= Stop bits 1, 2
X4*
= Port timeout interval (in 10-second increments) 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
NOTE: X4# through X4* are variables for the RS-232 inserts. These variables are repeated on page 69 as X6% through X6( and X7& for
the rear panel Remote RS-232 port.
X4( = UART starting point The starting point (X4() is the rear panel Remote RS-232 port.
The next four positions (X4(
+1
through X4(
+4
) are DTP inputs.
The next four positions (X4(
+5
through X4(
+8
) are DTP outputs.
Default values: 2000 = Rear panel Remote (RS-232) port
2001 through 2004 = Input 7 through input 10
2005 through 2008 = Output 5 through output 8