35
1
2
3
4
5
6
7
8
9
10
11
12
13
F
MOTORENCODER
J20A
ON
43
1 2
J1
J16
J13
J8
DL8
J6
J4
J5
DL9
DL10
RL1
J17
J20
IC1
SW2
SW4
SW3
SW1
DS1
J7
DL3
DL7
DL1
DL2
DL4
DL5
DL6
J10
J19
BATTERY
POWER
24V
POWER
SUPPLY
USB
2EASY
KEEPER
PHOTOCELLS
LOCK
ACCESSORIES
OPTIONS
LCD MODULE
J20B
ETH MODULE
RADIO MODULE
E100 - E140 CONTROL BOARD
LED ON OFF
DL1 (I-DET) input
I-DETclosed inputI-DETopen
DL2 (E-DET) input
E
-DET
closed inputE
-DET
open
DL3 (KEY) input KEY closed input K
ey open
DL4 (EM1) inputEMERG.1closed inputEMERG.1open
DL5 (EM2) input
EMERG
.2
closed inputEMERG
.2
open
DL6 (P1) input P 1 closed input P 1 open
DL7 (P2) input P 2 closed input P 2 open
DL8 (ERROR) see table below
POWER MainspowersupplyON MainspowersupplyOFF
24V= + 24V= present + 24V= absent
LED ERROR STATUS MEANING
OFF normal operating condition
ON microprcessor E140 control board broken
FLASHING power-on
PUSH-BUTTON
MEANING
SW1 executesautomaticSETUP/RESET
SW2 “F” programming push-button
SW3 “+” Programming push-button
SW4 “-” Programming push-buttons
DS1 ON OFF
Dip n°1 Pair of button photocells No. 1 present Pair of button photocells No. 1 absent
Dip n°2 Pair of button photocells No. 2 present Pair of button photocells No. 2 absent
Dip n°3
EMERG2activatesNIGHTfunction EMERG2standardfunction
Dip n°4 motor rotation direction (see table)
CONNECTOR MEANING
J1 Mainpowersupply36V4A
J4 Button photocells XF A
J5
Motorlock
J6 SD-Keeper-SDKLight
J7 Inputs and power supply for accessories
J8 USB port for connection to PC
J10 BUS - 2 EASY (for future use)
J13 Motor
J16 Emergency battery
J17 Motor
encoder
J18-
J19 LCD
Display
J20-J20A-
J20B
Optional modules:
- radio module (for E100 e E140)
- Eth module (only for E140)