EasyManuals Logo

Fagor DDS User Manual

Fagor DDS
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
Drive modules
188
3.
DRIVE MODULES
Compact drives
150
DDS
HARDWARE
Ref.1310
For a switching frequency fc = 4 kHz
F. H3/88
Current derating on “ACD/CMC 1.08” drives for fc = 4 kHz.
F. H3/89
Current derating on “ACD/CMC 1.15” drives for fc = 4 kHz.
F. H3/90
Current derating on “ACD/CMC 1.25” drives for fc = 4 kHz.
F. H3/91
Current derating on “ACD/CMC 2.35” drives for fc = 4 kHz.
F. H3/92
Current derating on “ACD/CMC 2.50” drives for fc = 4 kHz.
35 40 55 60
4
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
0
2
6
In
ACD/CMC 1.08
T ambient In
° C °F Arms
35 95 4.0
40 104 4.0
45 113 4.0
50 122 3.5
55 131 2.8
60 140 2.1
35 40 55 60
6
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
5
7
8
In
ACD/CMC 1.15
T ambient
In
° C °F Arms
35 95 7.5
40 104 7.5
45 113 7.5
50 122 7.0
55 131 6.3
60 140 5.5
35 40 55 60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
10
In
11
12
13
ACD/CMC 1.25
T ambient In
° C °F Arms
35 95 12.5
40 104 12.5
45 113 12.5
50 122 11.9
55 131 11.2
60 140 10.5
35 40 55 60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
12
In
14
16
18
ACD/CMC 2.35
T ambient In
° C °F Arms
35 95 17.5
40 104 17.5
45 113 17.5
50 122 16.3
55 131 14.7
60 140 13.2
35 40 55 60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
20
In
22
24
26
ACD/CMC 2.50
T ambient In
° C °F Arms
35 95 25.0
40 104 25.0
45 113 25.0
50 122 23.8
55 131 22.1
60 140 20.2