EasyManuals Logo

Fagor DDS User Manual

Fagor DDS
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #151 background imageLoading...
Page #151 background image
Drive modules
DRIVE MODULES
Compact drives
3.
151
DDS
HARDWARE
Ref.1310
For a switching frequency fc = 8 kHz
F. H3/93
Current derating on “ACD/CMC 1.08” drives for fc = 8 kHz.
F. H3/94
Current derating on “ACD/CMC 1.15” drives for fc = 8 kHz.
F. H3/95
Current derating on “ACD/CMC 1.25” drives for fc = 8 kHz.
F. H3/96
Current derating on “ACD/CMC 2.35” drives for fc = 8 kHz.
F. H3/97
Current derating on “ACD/CMC 2.50” drives for fc = 8 kHz.
35 40 55 60
4
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
0
2
6
In
ACD/CMC 1.08
T ambient In
° C °F Arms
35 95 4.0
40 104 4.0
45 113 4.0
50 122 3.7
55 131 3.2
60 140 2.7
35 40 55 60
7
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
6
8 In
ACD/CMC 1.15
T ambient In
° C °F Arms
35 95 7.5
40 104 7.5
45 113 7.5
50 122 6.9
55 131 6.4
60 140 5.9
35 40 55 60
9
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
8
10
In
ACD/CMC 1.25
T ambient In
° C °F Arms
35 95 9.5
40 104 9.5
45 113 9.5
50 122 9.0
55 131 8.5
60 140 7.9
35 40 55 60
16
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
15
17
In
18
ACD/CMC 2.35
T ambient In
° C °F Arms
35 95 17.5
40 104 17.5
45 113 17.5
50 122 17.0
55 131 15.9
60 140 14.9
35 40 55 60
18
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
17
19
In
20
ACD/CMC 2.50
T ambient In
° C °F Arms
35 95 20.0
40 104 20.0
45 113 20.0
50 122 19.1
55 131 17.8
60 140 16.4