Asynchronous spindle motor and servo drive selection
214
DDS
HARDWARE
Ref.1310
The power required in this case P
F
is calculated as follows:
Power needed to accelerate and decelerate an asynchronous spindle
motor
There are three methods to control the acceleration and deceleration pro-
cess of the machine spindle:
Acceleration limited by time.
Different acceleration ramps depending on the speed reached.
F. H5/7
Frictional load. Required power.
µ
Friction coefficiente
Mechanical efficiency
m
L
Table mass in kg
V
Linear speed in m/min
F. H5/8
Acceleration limited by time.
T. H5/2 Acceleration limited by time.
Method Acceleration limited by time.
Control Speed increases linearly in time until the command
speed is reached.
Comment The acceleration torque is constant.
F. H5/9
Different accelerations depending on speed.
Load
Motor
Speed
P
F
·m
L
·V
6120·
=
(kW)
adjust
time
0
Ta
speed
adjust
time
0
Ta
speed