Installation
312
8.
INSTALLATION
System installation
278
DDS
HARDWARE
Ref.1310
Adjust the modules through the RS-232 serial line using the application
for PC (WinDDSSetup).
Electrical precautions
Once the installation is completed and before doing anything with the servo
drive system:
INFORMATION. Remember that FAGOR provides all the cables needed
for the installation. If the user chooses to make his own cable, - see chapter
7. CABLES - that indicates the pinout of the connectors at both ends, me-
chanical characteristics and other considerations.
INFORMATION. In order for the FAGOR Servo System to meet the Euro-
pean Directive on Electromagnetic Compatibility 2004/108/EC, the mod-
ules installation rules must be strictly followed regarding:
• Installation of the “MAINS FILTER A”.
• Electrical installation of the power stage: wiring to mains and motor-
drive power connection.
WARNING. The system must always be installed before applying voltage
according to the EN 60204-1 standard. Ignoring it may cause serious inju-
ries, even death.
WARNING.
• Always disconnect all power supplies, including the external power that
feeds the control board that could be present.
• Wait at least 4 minutes until the capacitors of the DC bus are fully dis-
charged. Make sure that the DC BUS voltage is lower than 42 V DC.
• Install and close all covers and ground the drive system before applying
voltage
• Turn off the mains voltage using an appropriate switch to achieve a volt-
age-free condition.
MANDATORY. The cross section of the protective ground conductor must
comply with the applicable standards. Ground the cable shields at both
ends; however, the shields are not protective ground conductors.