162187 Manual Fältcom ECII® Flex V024D 2016-02-23 Page 21 of 41
Number for separate test alarm/routine call receiver
2.
Enter the telephone number of the test alarm/routine call receiver:
From keypad:
<Telephone number (max 20 digits)>
From phone:
300 < telephone number > #
3. Enter alarm code for the test alarm/routine call:
From keypad:
<Code (max 10 digits)>
From phone:
301 < Code (max 10 digits) > #
4.
To verify the test alarm/routine call function:
From keypad:
From phone:
300 #
Please view section 6.9 for priority order on test of receiver.
To delete the test alarm/routine call receiver, test alarm/routine call interval and test
alarm/routine call code:
From keypad:
From phone:
# 300 #
To disable test alarms/routine calls (leaves alarm receiver and code intact, but no test
alarms/routine calls will be made until a new interval is programmed):
1 a. From keypad:
From phone:
# 080 #
1 b. From keypad:
From phone:
# 082 #
6.13 Incoming calls
It is possible to call the lift phone and talk to the trapped person. If there is only one Fältcom
ECII® Flex on the line the unit can be set to answer immediately without selecting unit ID;
please see section Single unit. If there are multiple units sharing the line each unit require a
unique ID; ID 1 is the default setting but can be changed, the Fältcom ECII® Flex can also be
blocked from receiving speech calls: