Fält Communications 2016 ©
162187 Manual Fältcom ECII® Flex V024D 2016-02-23 Page 29 of 41
From phone: 601 <xx> #
To reset the alarm type to the default value, enter:
From keypad:
From phone:
# 601 #
Programmable alarm type alarm input 3
Same functionality as for alarm input 1. Changed by:
From keypad:
<XX>
From phone:
602 <xx> #
To reset the alarm type to the default value, enter:
From keypad:
From phone:
# 602 #
Note that Fältcom ECII® Flex always assumes that the programmed alarm type is
speech-connecting by default, see section Alarm input setting for setting technical si-
lent alarms.
6.22 Info Alarm – logging of alarms
Info Alarm will send a silent alarm after an emergency alarm using the alarm type 89d (59h).
This alarm can be used to access a log in an alarm receiver if the lift call has been sent to a
regular telephone. The Info alarm will use the specified Info Alarm code or if not programmed
it will use the Alarm Code 1, then add the alarm type of the alarm input, e.g.:
Lift alarm call to number 123 456 using alarm code 789 and alarm type 10. The Info alarm
receiver is programmed to call 654 321 but no code. After the lift alarm the Info alarm will then
call receiver 654 321 using alarm code 78910 and alarm type 89.
The Info Alarm is activated by programming:
From keypad:
<Telephone number (max 20 digits)>
From phone:
800 < Telephone number > #
Enter Alarm code:
From keypad:
<Alarm code (max 10 digits)>