162187 Manual Fältcom ECII® Flex V024D 2016-02-23 Page 24 of 41
swer time must be changed to ‘4’ on the Fältcom ECII® Flex as well.
6.15 Technical & Battery alarm receiver
It is possible to send all technical alarms from alarm input 2 and 3 and also battery alarms to
a dedicated alarm receiver. This is activated by:
From keypad:
<Telephone number (max 20 digits)>
From phone:
310 < telephone number > #
Enter Alarm code:
From keypad:
<Alarm code (max 10 digits)>
From phone:
311 < Alarm code (max 10 digits) > #
Deactivate function:
From keypad:
From phone:
# 310 #
Test of the alarm receiver:
From keypad:
From phone:
310 #
After exiting the programming mode, the phone will make a technical alarm call.
6.15.1 Battery alarm from Power Supply (art. 2001)
Battery back-up power is available using the Power Supply unit (art. 2001). The Power Supply
will generate a battery alarm when the battery power is low. The lift phone will send the bat-
tery alarm to the receiver using alarm type 17d (CPC protocol specific). When the Fältcom
ECII® Flex sends a battery alarm; change the battery in the Power Supply and push the “Re-
set” button. The lift phone will then send a battery reset alarm using alarm type 12d (CPC pro-
tocol specific). Battery alarm is default deactivated in the ltcom ECII® Flex.
Activate battery and battery reset alarms from Power Supply:
From keypad:
From phone:
330 #
To return to default setting, disabling battery and battery reset alarms: