Fält Communications 2016 ©
162187 Manual Fältcom ECII® Flex V024D 2016-02-23 Page 30 of 41
From phone: 801 < Alarm code (max 10 digits) > #
For deactivation of function:
From keypad:
From phone:
# 800 #
For test of the alarm receiver program:
From keypad:
From phone:
800 #
Observe that if the main alarm was never acknowledged, no Info Alarm will be sent out. Also,
this function will not dial out an Info Alarm following battery alarms nor test alarms/routine
calls or end-of-alarm.
6.23 End-of-alarm
To ensure that a trapped passenger is actually released from the lift there is a function which
sends an end-of-alarm call with a specific alarm type to the alarm receiver. Alarm type is de-
fault 28.
This alarm is activated by the rescue service by pressing a magnet to the front of the Fältcom
ECII® Flex after having released the trapped person. See drawing below for location of the
magnetic switch. This is default deactivated. For activation or changing then alarm type:
For activation of magnetic switch:
From keypad:
From phone:
620 #
From keypad:
From phone: # 620 #
For activation of magnetic switch and setting a different alarm type:
From keypad:
< alarm type >
From phone: 620 < alarm type > #
It is also possible to specify that the magnetic switch should only be active for 6 hours after an
emergency alarm. This function is activated using:
From keypad:
From phone: 621 #