162187 Manual Fältcom ECII® Flex V024D 2016-02-23 Page 23 of 41
To go back to default settings program:
From keypad:
From phone:
140 < 1 > #
6.13.3 Active alarm mode
This alarm mode opens the Fältcom ECII® Flex for incoming calls for 6 hours after an alarm
call has been triggered. After this time the lift phone will be closed for incoming calls until a
new alarm is triggered.
To activate the Active alarm mode the following conditions must be fulfilled:
Active alarm mode function is programmed
A lift alarm has been called out
The active alarm mode is closed by pressing 5 on the receiving telephone or from the phone
that has called to the Fältcom ECII® Flex.
Alarm mode function is activated with:
From keypad:
From phone: 141 #
Alarm mode function is deactivated with:
From keypad:
From phone: # 141 #
The active alarm mode is automatically disconnected after 6 hours, but will be extended with
6 hours if a new speech connecting alarm is made or if a call is made to the Fältcom ECII®
Flex during this interval.
6.14 Answering time for incoming calls
The number of ringing signals before the Fältcom ECII® Flex answers incoming calls can be
changed. Default is 1 ringing signal and can be changed up to 30. This is changed by:
From keypad:
< 1-30 >
From phone:
050 < 1-30 >
Note: Older Fältcom lift phone models have an answer time of ‘4’ ringing signals before an-
swering. If a Fältcom ECII® Flex is sharing the line with older lift phone the ringing signal an-