USE AND MAINTENANCE MANUAL - SECTION 3
AERIAL PLATFORM ZP Rev. 05_2018
Page 3-3
FUNCTIONAL TEST
At the end of the "DAILY INSPECTION" (section n°6), carry out a functional
test of all systems in an area free from overhead obstacles and at ground
level.
ATTENTION
IF THE MACHINE DOES NOT WORK PROPERLY, SWITCH IT OFF
IMMEDIATELY. ALERT MAINTENANCE PERSONNEL TO THE PROBLEM. DO
NOT USE THE MACHINE UNTIL IT IS DEEMED SAFE TO USE.
Carry out a functional test as detailed below.
1. Carry out the operations as instructed from the ground controls,
without any load in the basket.
a. Operate the ground controls, lifting and lowering the work platform;
b. Ensure all machine functions are disabled when operating
(pressing) the emergency stop button;
c. Check correct operation of the manual descent valve.
2. Carry out the specified operations from the control console of the
cage.
a. Make sure the control console is correctly assembled and securely
fastened;
b. Lift and lower the work platform ensuring lifting and lowering take
place regularly;
c. Make sure all machine functions are disabled when operating
(pressing) the emergency stop button.