SECTION 8. MAINTENANCE OPERATING INSTRUCTIONS
BATTERY MAINTENANCE
It is necessary to periodically check for any corrosion and tightening of the
terminals.
Replace the batteries as follows:
1. Remove the cage;
2. Make sure the machine is not connected to the mains supply
(charging batteries);
3. Use the suitable switch to disconnect the machine's power supply;
4. Open the protective cover of the battery compartment;
5. Loosen the connection terminals of the batteries (positive pole and
negative pole);
6. Remove the batteries and replace them with new ones;
7. Connect the terminals of the batteries, making sure to do so correctly
(red wire for the positive pole, black wire for the negative pole) and
tighten them;
8. Close and lock the protective cover;
9. Position the cage again in the desired position, as indicated in
paragraph 4 “WORK PLATFORM CONFIGURATION”, being careful
to insert and lock the connecting pin correctly to the structure of the
extendible column;
10. Reconnect the power supply.