ATTENTION
THE RECOMMENDED FREQUENCY OF LUBRICATION AND OF THE WEAR
CHECKS IS BASED ON NORMAL USE. IF THE MACHINE IS USED FOR HEAVY
DUTY WORK, SUCH AS A HIGH NUMBER OF CYCLES, UNFAVOURABLE
POSITION, CORROSIVE/DIRTY ENVIRONMENT, ETC., THE USER MUST
INCREASE THE FREQUENCY OF THE CHECKS ACCORDINGLY.
MAINTENANCE EVERY THREE MONTHS
• Check there is no clearance, mechanical parts not correctly
secured and/or bent and no parts/components desoldered;
• Check the integrity of the structural profiles;
• Check correct operation of the emergency descent valve.
Take the cage to a height and execute an “emergency descent”, as shown
in the relative section of this manual.
• Hydraulic Oil
Check the level of hydraulic oil and top-up, if necessary.
Refer to the specifications described in the relative paragraph for
information regarding hydraulic oil checks and top-up;
• Check the hydraulic oil piping and make sure there are no leaks;
• Battery check (if applicable)
Periodically check for any corrosion and tightening of the terminals and
any acid top-ups required in the battery (if a lead/acid type).
• Check the cage and the entrance doors
Correct blocking of the cage and entrance doors operating correctly.