USE AND MAINTENANCE MANUAL - SECTION 5
AERIAL PLATFORM ZP Rev. 05_2018
Page 5-1
SECTION 5. EMERGENCY PROCEDURES
This section shows the operations to be carried out in the event of an
emergency during machine operation.
EMERGENCY OPERATION
Operator unable to control the machine
CONDITIONS IN WHICH THE MACHINE OPERATOR IS IMMOBILISED,
TRAPPED OR UNABLE TO OPERATE OR CONTROL THE MACHINE.
The other personnel must only operate the machine from the emergency
controls on the ground in case of absolute need.
The machine controls must only be used by qualified personnel.
INTERRUPT MACHINE ACTIVITY IF THE CONTROLS DO NOT
OPERATE CORRECTLY.
In case of incorrect operation of the controls or power outage, the
emergency stop must be operated and, if necessary, a qualified operator
must carry out the EMERGENCY DESCENT procedure from the ground.
Proceed as follows:
1. Press the emergency button to disconnect the power supply;
2. ATTENTION: make sure there are no persons within the working
range of the machine;
3. Gradually loosen the knurled knob installed underneath the base
carriage near the extensible framework, in order to obtain the
descent of the work platform (1);