D 22 83
3911 5848 9 Amber
Aftertreatment 1
SCR Intermediate
NH3
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Abnormal update rate
3912 5853 10 Amber
Aftertreatment 1
SCR Intermediate
NH3 Gas Sensor
Heater
Preliminary FMI
Aftertreatment 1 Outlet NH3 Gas Sensor Heater - Abnormal rate of
change
3917 104 18 Amber
Engine
Turbocharger
Lube Oil
Pressure 1
Engine Turbocharger Lube Oil Pressure - Data Valid But Below Nor-
mal Operating Range - Moderately Severe Level
3931 1109 0 Red
Engine Protection
System Approach-
ing Shutdown
Engine Protection System
Approaching Shutdown - Data valid but above normal operational
range
- Most
3932 5851 16 Amber
Aftertreatment 1
SCR Intermediate
NH3 Gas Sensor
Power In Range
Aftertreatment 1 SCR Intermediate
NH3 Gas Sensor Power Supply - Data Valid But Above Normal
Operating Range – Most Severe
Level
3933 5851 18 Amber
Aftertreatment 1
SCR Intermediate
NH3 Gas Sensor
Power In Range
Aftertreatment 1 SCR Intermediate
NH3 Gas Sensor Power Supply - Data Valid But Below Normal
Operating Range – Most Severe
Level
3934 5851 2 Amber
Aftertreatment 1
SCR Intermediate
NH3 Gas Sensor
Power In Range
Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply -
Data erratic, intermittent or incorrect
3935 5848 13 Amber
Aftertreatment 1
SCR Intermediate
NH3
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Out of Calibration
3936 5848 12 Amber
Aftertreatment 1
SCR Intermediate
NH3
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Bad intelligent device or component
3937 5848 10 Amber
Aftertreatment 1
SCR Intermediate
NH3
Aftertreatment 1 SCR Intermediate
NH3 Sensor - Abnormal rate of change
3988 3265 9 Amber
Aftertreatment 2
Outlet NOx
Aftertreatment 2 Outlet NOx -
Abnormal Update Rate
4143 5741 3 Amber
Aftertreatment 1 Outlet Soot Sensor
- Voltage Above Normal, or Shorted to High Source
4144 5741 4 Amber
Aftertreatment 1 Outlet Soot Sensor
- Voltage below normal, or shorted to low source
4145 3255 9 Amber
Aftertreatment 2
Intake NOx
Aftertreatment 2 Intake Nox Sensor -
Abnormal update rate
4151 5742 9 Amber
Aftertreatment Diesel Particulate
Filter Temperature Sensor Module - Abnormal update rate
Diesel Engine Failure-Codes chart