EasyManuals Logo

Ferroli OMNIA HYBRID C User Manual

Ferroli OMNIA HYBRID C
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
EN
Cod. 3541T090 - Rev. 00 - 06/2019
TECHNICAL DATA AN PERFORMANCE
2. TECHNICAL DATA AN PERFORMANCE
2.1 System technical data
- Mod.
04
06
08
ERP class in heating / Seasonal efficiency
medium temperature (produced water 55°C)
(Class G - A++)
A
++
127
A
++
133
A
++
126
ERP class in heating / Seasonal efficiency
low temperature (produced water 35°C)
(Class G - A++)
A
++
183
A
++
187
A
++
171
Electric power supply V-ph-Hz 220-240V ~ 50 Hz
Type of compressor - Twin Rotary
No. of compressors / No. of cooling circuits
No.
1/1
Type of exchanger system side - piastre inox saldobrasate
Type of exchanger source side - batteria alettata
Type of fans - brushless DC
No. of fans
No.
1
Cooler fittings - liquid line ø 9,52
Cooler fittings - gas line ø 15,88
Internal unit expansion vessel volume l 8
SWL - External unit sound power level* dB(A) 62 66 69
SWL - Internal unit sound power level* dB(A) 43
External unit weight kg 60 60 76
Internal unit weight kg 43
NOTA: The values refer to units without any optional features or accessories.
Data declared according to EN 14511:
EER (Energy Efficiency Ratio) = ratio of cooling capacity in relation to absorbed power
COP (Coefficient Of Performance) = ratio of heat output in relation to absorbed power
A7W35 = source : air in 7°C b.s. 6°C b.u. / system : water in 30°C out 35°C
A7W45 = source : air in 7°C b.s. 6°C b.u. / system : water in 40°C out 45°C
A35W18 = source : air in 35°C b.s. / system : water in 23°C out 18°C
A35W7 = source : air in 35°C b.s. / system : water in 12°C out 7°C
NOTE: Efficiency class calculated according to European regulation 811/2013. The values refer to units
without any optional features or accessories.
2.2 Heat pump technical data
- Mod. 04 06 08
A7W35
Heating capacity kW 4,1 6,1 8
Total power input kW 0,82 1,29 1,73
COP W/W 5 4,73 4,62
Water flow rate l/h 705 1049 1376
Available pressure heat without cocks kPa 72 66 54
Available pressure heat with cocks kPa 68 57 39
A7W45
Heating capacity kW 4,01 5,96 7,34
Total power input kW 1,13 1,68 2,13
COP W/W 3,55 3,55 3,45
Water flow rate l/h 690 1025 1262
Available pressure heat without cocks kPa 72 67 58
Available pressure heat with cocks kPa 68 58 45
A35W18
Cooling capacity kW 4,1 6,2 8
Total power input kW 0,84 1,43 1,93
EER W/W 4,88 4,34 4,15
Water flow rate l/h 705 1066 1376
Prevalenza utile disponibile senza rubinetti kPa 72 66 54
Prevalenza utile disponibile con rubinetti kPa 68 57 39
A35W7
Cooling capacity kW 4,12 6,15 6,44
Total power input kW 1,3 2,08 2,24
EER W/W 3,17 2,96 2,88
Water flow rate l/h 709 1058 1108
Available pressure heat without cocks kPa 72 66 64
Available pressure heat with cocks kPa 68 57 54
IThe values refer to units without any optional features or accessories.
Data declared according to EN 14511:
EER (Energy Efficiency Ratio) = ratio of cooling capacity in relation to absorbed power
COP (Coefficient Of Performance) = ratio of heat output in relation to absorbed power
A7W35 = source : air in 7°C b.s. 6°C b.u. / system : water in 30°C out 35°C
A7W45 = source : air in 7°C b.s. 6°C b.u. / system : water in 40°C out 45°C
A35W18 = source : air in 35°C b.s. / system : water in 23°C out 18°C
A35W7 = source : air in 35°C b.s. / system : water in 12°C out 7°C
NOTE: Efficiency class calculated according to European regulation 811/2013. The values refer to units
without any optional features or accessories.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ferroli OMNIA HYBRID C and is the answer not in the manual?

Ferroli OMNIA HYBRID C Specifications

General IconGeneral
BrandFerroli
ModelOMNIA HYBRID C
CategoryHeat Pump
LanguageEnglish

Related product manuals