2. Commissioning
2−10
Festo P.BE−CPX−FB38−EN en 0804NH
The manuals for the pneumatic valve cluster (Midi/Maxi, CPA,
MPA and VTSA/VTSA−F or ISO) contain the address assign
ment within the pneumatic modules.
For further inform. on MPA pneum. modules andthepneum. in
terfaces: see manual for the CPX I/O modules (P.BE−CPX−EA−...).
CPX pneumatic interfaces for
MPA and related modules
Module type Module
identifier
1)
Assigned
address space
Inputs Outputs
Pneumatic interface for MPA or
MPA−F valves (type 32/33)
VMPA−FB−EPL−...
MPA1 pneumatic module (type 32/33)
without electrical isolation
VMPA1−FB−EMS−8
2)
(CPX type 32/33: 1−8V...)
MPA1S 1 byte/
8 O
MPA1 pneumatic module (type 32/33)
with electrical isolation
VMPA1−FB−EMG−8
2)
(CPX type 32/33−G: 1−8V... )
MPA1G 1 byte/
8 O
MPA2 pneumatic module (type 32/33)
without electrical isolation
VMPA2−FB−EMS−4
2)
(CPX type 32/33: 1−4V...)
MPA2S 1 byte/
4 (8) O
3)
MPA2 pneumatic module (type 32/33)
with electrical isolation
VMPA2−FB−EMG−4
2)
(CPX type 32/33−G: 1−4V... )
MPA2G 1 byte/
4 (8) O
3)
MPA1 pneumatic module (type 32/33)
without electrical isolation,
with diagnostic function D2
VMPA1−FB−EMS−D2−8
2)
(CPX type 32/33: 1−8V...)
MPA1S−D 1 byte/
8 O
MPA1 pneumatic module (type 32/33)
with electrical isolation,
with diagnostic function D2
VMPA1−FB−EMG−D2−8
2)
(CPX type 32/33−G: 1−8V... )
MPA1G−D 1 byte/
8 O
MPA2 pneumatic module (type 32/33)
without electrical isolation,
with diagnostic function D2
VMPA2−FB−EMS−D2−4
2)
(CPX type 32/33: 1−4V...)
MPA2S−D 1 byte/
4 (8) O
3)
MPA2 pneumatic module (type 32/33)
with electrical isolation,
with diagnostic function D2
VMPA2−FB−EMG−D2−4
2)
(CPX type 32/33−G: 1−4V... )
MPA2G−D 1 byte/
4 (8) O
3)
1)
Module identifier in the handheld unit or in the hardware config. of the programming software
2)
Type of electronic module used
3)
4−way modules MPA2 always occup y 8 I (1 byte) of address space (4 I or 8 bits remain unused)
Tab.2/4: Overview of CPX pneumatic interfaces and pneumatic modules (part 1)