7 BLVT-blanking functions -Programmers
7.4 Programmers for programming the blanking functions.
For detailed directions please refer to the instruction manuals for the respective Programmers!
The programming remains permanently stored within the BLVT-Light curtains even after a voltage interruption.
7.4.1 PLSG3/K: Universal switching unit and Programmer for BLVT blanking functions.
Simple programming procedure (for more detailed instructions please refer to the operating instructions PLSG )
The programmer PLSG3 simply snaps onto the light curtain or can be connected by an adaptor cable.
1. The programming of the blanking function is realized by 4 HEX switches.
2. The objects to be blanked must be located within the protecting field.
3. then, just connect the operating voltage. The selected blankling function and the blanking position will be saved perman
ently by the BLVT-light curtain.
The programmer is not necessarily required for the operation of the BLVT and may be removed after having terminated the
programming.
7.4.2 BLPG: Blanking-Programmer.
The programming of the blanking function is realized by 4 HEX switches. The programmer is not necessarily required for the
operation of the BLVT and may be removed after having terminated the programming.
7.4.3 BPSG: Blanking-Programmer and switching unit
same as BLPG, but provides additional power supply and positively driven relais with potential-free outputs. Programming is
made by activating a key-switch.
Easy and simple programming procedure: (valid only for the switching units BLPG und BPSG)
(please refer to the detailed instructions in the operating instructions BPLG/BPSG )
1. Enter the desired blanking function via the DIP-switches.
2. The objects to be blanked must be located within the protecting field.
3. Turn the key switch into the "Programming"-position. Wait until the green LED at the switching unit indicates that the
switching unit is now ready to be programmed.
4. Remove the key switch from its lock. When the green LED "AKTIV" is off, the programming procedure is terminated.
7.5 How to save up to 5 different blanking patterns and how to activate them via selector switch
The BLVT in connection with the programmers BLPG or BPSG and an external selector switch is able to save up
to 5 different blanking patterns, which can be activated via this selector switch.
For this function, please refer to the detailed instructions in the operating instructions of the programmers!
Nr. /Ba uja hr No./ year of cons tr uct io n .................................
Temp. temp. -10 + 55 °C
Schut zart enc losure r ating IP 20
Vers orgung supply voltage 24 VDC -10% + 20 %
FIESSLER
E L E K T R O N I K
Typ: BLPG
Kastellstr.9 73734 Esslingen
Tel. 0711/ 91 96 97-0
Achtung Vor Abzi ehen der Klemmle ist e Net zspan nung a bschal ten !
Attention Turn off the supply volt age !
Attention Cou per l 'a li ment ati on !
Made in
Germany
21
20
19 18
17
22
29
30
31
32
EDM-
BLVT
BLVT+
0V
24V
24
23
25
26
27
28
1
0
AKTIV
EDM-
MS
Auflösung kennzeichnen!
detection to be indicated!
detection ammoncez!
!
PE
S1 S2 S3 S4
1 1 1 1
1 0 0 0
0 1 0 0
0 0 0 1
0 0 1 0
0 0 1 1
1 1 0 0
14 / 30 mm
S3
S2
22 / 42 mm
29 / 56 mm
S1
Achtung Vor Abzi ehen der Klemmle ist e Net zspan nung a bschal ten !
Attention Turn off the supply volt age !
Attention Co uper l 'a li ment ati on !
FIESSLER
E L E K T R O N I K
Typ: BPSG
Kastellstr.9 73734 Esslingen
Tel. 0711/ 91 96 97-0
Made in
Germany
21
20
19 18
17
22
29
30
31
32
EDM-
BLVT
BLVT+
0V
24
23
25
26
27
28
1
0
AKTIV
EDM-
MS
Auflösung kennzeichnen!
detection to be indicated!
detection ammoncez!
!
PE
2
3
4
12
13
14
15
SK
230V
115V
---------- 24V ---------
N
16
11
ST
5
7
8
9
10
----- 0V -----
OSSD1
OSSD2
6
1
24V
Nr. /Ba uja hr No./ year of cons tr uct io n .................................
Anspr echzei t response time 6 mSs+ BWS / ESPE
Temp. temp. -10 + 55 °C
Schut zart enc losure r ating IP 20
Vers orgung supply voltage 230 VAC -15% +10 %, 50Hz
Kont aktbe l. contact max. 2 A, 250 VAC
S1 S2 S3 S4
1 1 1 1
1 0 0 0
0 1 0 0
0 0 0 1
0 0 1 0
0 0 1 1
1 1 0 0
14 / 30 mm
S3
S2
22 / 42 mm
29 / 56 mm
S1
Bild 32/1
fig 32/2
fig 32/3
FIESSLER
E L E K T R O N I K
32
Fiessler Elektronik GmbH & Co. KG
Doku Nr. 958 Stand 22.01.2018 RK
Phone: +49 (0) 711 / 91 96 97-0 Internet: http://www.fiessler.de
Fax : +49 (0) 711 / 91 96 97-50 eMail: info@fiessler.de

Table of Contents