16
5.3 DISARM/ MONITOR Mode: The LS-20 will not issue any alarm for Burglar sensors, but
24-Hour sensors, Fire sensors, Panic, Medical Buttons and Environment sensors still work all the time.
Enter into DISARM or MONITOR Mode from different devices or services.
Monitor Mode: In this mode all the trigger signals from the Burglar Sensors (not including the
sensors assigned in Group number 91-99 Partial Arm Zones) will be recorded in the
Event Log as trigger events only; no alarm will be issued. The purpose of this mode is
for the recording of all activities in the protected area while in Disarm Mode.
5.4 Reaction of LS-20 to Burglar Alarm
Burglar Alarm Response
AWAY Mode Entry Delay Burglar Alarm
Operation Mode
(0-255 seconds)
Burglar sensor triggered Siren goes off, Alarm data out.
Burglar alarms can only be issued when the system is in AWAY or HOME mode or with the sensors
assigned as a 24-Hour Zone device, while Fire, Panic, Medical and Environment alarms can be
triggered anytime, regardless of the system operation mode.
The siren can be stopped by disarming the system.