33
Inactivity Time (refer to Inactivity Time), the Inactivity Alarm (medical) will be issued.
Note: Inactivity function will be disabled in Away mode automatically and
will issue alarm if the Inactivity sensor is triggered.
Inactivity=No: This is a normal Burglar Sensor.
*Supervised: (Automatically set by the sensor itself, refer to Sensor Supervise Time.)
Supervised =Yes: System will check the “heartbeat” signal from this sensor.
Supervised =No: System will not check the “heartbeat signal from this sensor.
8.5 Special Settings for Environment Sensor:
Alarm High Limit/Alarm Low Limit: Set the High/Low alarm limits for the sensors with readings,
like temperature sensor. (please refer to the manual of the Sensor.)
Ex: Reading above 35 will trigger High Limit Alarm, Reading below 10 will issue Low
Limit Alarm. Empty value will not trigger any alarm.
Control (High Limit/Low Limit):
High Limit: For the control of cooler type device, it means when the reading is above the