26
Disarm Exit Delay AWAY ARM effective
System status:
(0-255 seconds)
Set AWAY mode
This Delay only works on the Controller with its Delay Activation = Yes, see below.
* Inner Siren Time: 0-255 seconds (default = 60 sec.)
The time of the Inner Siren sounds when the alarm trips.
*Alarm Siren Action Time: 0 second to 120 minutes (default = 60 sec.)
The activation time of the external Alarm Siren sounds (on the rear panel) when the alarm trips.
*Sensor Supervise Time: 0-24 Hours (default = 12 Hours)
The LS-20 is a supervised RF wireless system, meaning supervised sensors send heartbeat
RF signals to the Base Unit at a certain time interval. If the Base Unit does not receive the RF
check signal from a supervised sensor within the Sensor Supervise Time, the LS-20 considers
this sensor to be missing and issues a warning message.
This time can be set from 0 to 24 hours (0 hour means that the system will not check the
“heartbeat” signal.
Please note, the time shorter than 4 hours would increase sensor RF Loss possibility.