15
TROUBLE SHOOTING THE HYDRAULIC SYSTEM:
Symptom Probable Cause Remedy
Power feed motor will Plugged suction strainer. Clean strainer.
not run in either
direction.
Suction line valve closed. Open valve.
Collapsed suction hose. Replace hose.
Worn pump. Repair or replace.
Power feed chain runs Loose chain. Adjust tension on
unevenly. chains.
Power feed motor runs Flow control stuck Repair or replace.
in reverse only. or plugged.
Flow control cable Repair cable.
inoperative.
CLEANING AND MAINTENANCE:
CAUTION: Turn off engine and disconnect battery before servicing
equipment.
AFTER FIRST 100 HOURS OF OPERATION:
1. Check belt tension on the drive belt - see pages 16-17.
2. Check and adjust clutch - see page 19.
3. Retorque wheel lugs – again after 7 days.
DAILY CLEAN-UP MAINTENANCE:
Follow this procedure daily to keep the equipment in good operation condition:
1. Check the air cleaner on the engine by removing the element and checking the cleanliness of the
element by using a light inserted inside. If the light cannot be seen, element is dirty. Wash it with
clean water and detergent; do not use a pressure hose. If you cannot get it clean enough to see the
light, element should be replaced.