Installation Instructions
Seite/Page 74 - Kaptitel/Chapter 5: Installation Instructions 15.2.13
Fig. 5.8.3.2-3: Tilted position 30 degrees
Tilted position 30 degrees - Fig. 5.8.3.2-3
The distance between the hydrostatic head and the critical point at the exhaust elbow is only 216 mm. This means
that in a tilted position of 30 degrees you already face the highest risk of sea water sloshing into the combustion
chamber.
Fig. 5.8.3.2-4: Tilted position 45 degrees
Tilted position 45 degrees - Fig. 5.8.3.2-4
The water level is now at the same height as the critical point at the exhaust elbow. If the ship is sailed in a tilted
position of 45 degrees with an installation like this, the ingress of cooling water into the combustion chamber is inev-
itable. Irreparable damages are preprogrammed.