EasyManua.ls Logo

Fischer Panda 10000i PMS - Environmental Protection; Maintenance Requirements; Maintenance Interval; Check of Hoses and Rubber Parts in the Sound Insulated Capsule

Fischer Panda 10000i PMS
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Instructions
15.2.13 Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 97
7.3 Environmental protection
Environmental protection.Danger to the environment due to mishandling!
Significant environmental damage can occur, particularly for incorrect dis-
posal, if environmentally hazardous operating materials are mishandled.
Therefore:
• Always observe the instructions mentioned below.
• Take immediate action if environmentally hazardous mate-
rials reach the environment. Inform the responsible local au-
thorities about the damage in the case of doubt.
The disposal must be performed by a specialist disposal
company.
7.4 Maintenance Requirements
Control before starting
• Oil level
• Cooling system leaks
• Visual check for any changes, leaks oil drain system, v-belt,
cable connections, hose clips, air filter, fuel lines
Once a week
• Lubrication of actuator-trapezoid thread spindle
7.5 Maintenance interval
For the maintenance intervals, see the „General information for vehicles generators“ which are attached to this man-
ual.
For generators with dynamic maintenance interval (for example generators with iControl2). Further informations are
in the remote control panel manual/data sheet.
Note:
With the dynamic operation hours the service interval can be
raised up to 30% (200h max.). Make sure that the dynamic oper-
ation hours are not reset accidently between the service inter-
val.
7.5.1 Check of hoses and rubber parts in the sound insulated capsule
Check all hoses and hose connections for good condition. The rubber hoses are very sensitive to environmental
influences. They wear quickly in an environment of dry air, oil and fuel vapours, and high temperatures. The hoses
must be checked regularly for elasticity. There are operating situations, when hoses must be renewed once a year.