Installation Instructions
Seite/Page 86 - Kaptitel/Chapter 5: Installation Instructions 15.2.13
Fig. 5.11.1-1: Positive Battery Cable Positive battery cable
The positive (+) battery cable is connected directly to the solenoid switch of
the starter.
Fig. 5.11.1-2: Negative Battery Cable
Negative battery cable
The negative (-) battery cable is connected to the engine foot.
Note! The battery negative pole may not be connected with the
boat ground or with the protective grounding of the 120 V
installation!
Fig. 5.11.1-3: DC Starter Motor DC Starter Motor
All Panda generators are equipped with an independent DC starter motor.
1. Solenoid switch for starter motor
2. Starter motor